To make the dust collector purification system to play its due effect, from the organization production point of view must pay attention to the following questions:
1. To be equipped with specialized personnel to manage and maintain the purification system.
2. Should be customized for the specific circumstances of the purification system operation and management system, such as job responsibility system, transfer system testing system, equipment maintenance, maintenance system.
3. Should be emphasized between the various types of work with each other.
1) Purification system in the adjustment is completed, the adjustment valve should be fixed, the operation may not be arbitrarily changed. When a system links a few exhaust points, if an exhaust point of the process equipment to stop running, the exhaust hood should not be closed, so as not to change the other exhaust hood exhaust volume.
2) Should be in accordance with the provisions of the process equipment and purification equipment between the car, parking order opening and closing equipment. The general dust removal device should be started before the start of the process equipment and shut down after the process equipment has stopped for 5 minutes to prevent the deposition of dust and other substances in the equipment and ducts. To prevent overloading of the motor, especially for high temperature flue gas purification systems, Adjust the total valve opening, in the case of reducing the amount of air to start.
3) Run time should be a good run log, log content, including shift time and shift shift situation, the time of operation of the equipment during the time, a variety of equipment, parking time and its causes. When the equipment occurs the situation, should be recorded in detail the causes of the failure, the situation and the reference for maintenance and so on. Run the time to record the relevant parameters of the purification system.
4) Should strengthen the routine maintenance of equipment, routine maintenance of the main task is to eliminate equipment, pipes, exhaust hood, cleaning holes, observation holes, ash valve, etc. leakage. Adjust the system for the amount of air flow and wind pressure, remove all possible hidden trouble.
5) Regularly remove the pipeline and the equipment within the dust and other sediments.
6) To strengthen the maintenance of equipment. According to the actual situation to determine the maintenance of the content, time, methods and requirements.
Contact: Jane
Phone: +86-136 0202 1569
E-mail: info@sinobaghouse.com